Ballasts, Electronic
536464 | Manufacturer: Philips | EAN: 8711500536464 | MPN: 913700418366
The HF-Matchbox Blue 121 LH TL5 230 240V is an affordable, reliable, and compact high-frequency ballast . With a robust design and meeting international safety standards, it offers energy efficiency (CELMA EEI) of A2. Perfect for indoor applications like spotlights and emergency fixtures in retail stores, hotels, and residential buildings.
Lamp Type TL5
Number of Lamps 1 piece/unit
Number of Products on MCB (16 A Type B) 59
Automatic Restart Yes
Input Voltage 230 - 240 V
Input Frequency 50 - 60 Hz
Power Factor 100% Load 0.64
Ignition Time (Max) 0.5s
Mains Voltage Performance (AC) -8%…+6%
Mains Voltage Safety (AC) –10%…+10%
Power Losses 2.4 W
Connector Type Input Terminals Insert
Color Input Terminals Grey
Color Output Terminals Grey
Connector Type Output Terminals Insert
Cable Length From Device to Lamp 1.50m
Cable Length Hot Wiring 0.30m
Wire Striplength 8.0-9 mm
Input Terminal Cross Section 0.50 - 1.50 mm²
Output Terminal Cross Section 0.50 - 1.50 mm²
Rated Ballast-Lamp Power 21 W
T-Ambient (Max) 40 °C
T-Ambient (Min) –10 °C
T-Case Maximum (Max) 75 °C
Housing LH
Battery Voltage Lamp Ignition 194-254 V
IP Classification IP 20 [ Ingress Protection 20]
Approval Marks F-Marking, CE marking, VDE certificate, CB Certificate
Length A1 187 mm
Fixing Hole Distance Length A2 180 mm
Width B1 22 mm
Height C1 22 mm
Fixing Hole Diameter D1 4.4 mm
Benefits
• Automatic restart (after voltage dip or lamp exchange) ensures easy operation and hassle-free re-lamping.
• Suitable for use in class I or class II luminaires
Features
• Suitable for emergency DC operation between 190 and 254 V
• Programmed, flicker-free, pre-heated start (<0.8 sover8000onoffswitchesonelampdependingballastcombinationbr>• Automatic restart (after voltage dip or lamp exchange) ensures easy operation and hassle-free re-lamping.
Applications
• Used with movement-detection control systems like Philips OccuPlus in applications where lamps burn for a long period of time and the switching cycle is infrequent (e.g. a maximum of three times per day)
• Mainly for indoor applications such as spotlights, downlights, light boxes, and emergency and security fixtures used largely in retail stores, office buildings, hotels, private homes and residential buildings
• Domestic applications such as outdoor garden lighting, garage areas, stairways